The lower surface of the focusing lens in the condenser may also be contaminated by volatile organic compounds from the workpiece.
Therefore, during production and processing, it is necessary to pay attention to the exhaust system and air blowing inspection and maintenance to minimize the contamination of the condenser. If the damage is serious, the following methods can be used for cleaning:
(1) Remove the blowpipe, pressure ring and maintenance sleeve, and carefully remove the condenser;
(2) Use a blower to blow away the dust on the surface of the condenser;
(3) Use medical tweezers to carefully pinch the cotton ball and dip it in industrial ethanol or special lens cleaning fluid to gently wipe it. It should be gently wiped from the inside to the outside in one direction. After each wipe, the cotton ball needs to be replaced until the waste is removed.
It must be noted that when wiping, you should wipe in the same direction, not back and forth, and not to be scratched by sharp objects, because the surface of the
Air Cooling Suitecase Pulsed Laser Cleaner dual-light lens is coated with an anti-reflection film. If the film is damaged, it will seriously affect the power output of the Laser
Cleaning Machine.